Monday, April 27, 2009

Air conditioner

System Residues hide leaks. Sludge and residues coat the interior of system components and temporarily seal corrosion pits, fissures, seams, seals, o’rings, and other small leak points. Some of those residues include refrigeration oils, acids, desiccant, pulverized metal, Teflon piston ring material, brazing fluxes, dye particles, etc.

Overcoming Residue Surface Tension: Leaks are harder to find because leak testing is performed with the system turned off. Lost are the benefits of an operating system: a) constant washing of interior surfaces of components; b) higher operating pressures that encourage leaks. With a system at rest, the undisturbed residues mentioned above are able to coat the insides of the evaporator, condenser, compressor, and other components. When Residue Surface Tension is greater than the interior pressures’ ability to displace it, there is no leak occurrence, thus no leak detection.Residue Displacement

If surface tension is the culprit, then how do we overcome it? Answer: By adding 4-ounces of chlorine-based refrigerant R-22 to the system. R-22 disturbs the surface tension. We follow that by pressurizing the system with 175-200 psi of nitrogen. Both are cheap.
At the higher system pressure, the R-22 overcomes the residue surface tension and forces the leak path to reopen. Now, enough R-22 gas is available so that leaks are detected easily. The R-22 is the residue-displacing agent.